The Sentry Xpress 4.0 micro processor is manufactured by the
Orton Ceramic Foundation and displays the CE mark.
Hr./Min.
When Lit
HIGHER
°C
°F
When Off
When Lit
START/
STOP
LOWER
Program
Review
Run
MICRO PROCESSOR
TM
SENTRYXpress
4.0
Enter
Program
Skip Seg.
Add Hold
Change Temp.
T/C Offset
Alarm
Delay
Review
1
START/STOP Key
Starts and stops a firing.
Press after each
programming step. It works like the
Enter key on a computer.
Up Arrow Key
From
press .Press
to select Single-Speed or
Ramp-Hold. Pages 6, 8
During a
Ramp-Hold firing, press the
. will appear. Press
. The current segment ramp
or hold number will appear. To
skip, press again. Page 8
During a
Ramp-Hold firing, press
repeatedly until appears.
Press .Eachtimeyoupress
the , the hold time for the
current segment will increase by 5
minutes. Then press .
Page 8
During a Ramp-Hold firing,
press repeatedly until
appears. Press .Use
the arrow keys to change the target
temperature for the current seg
-
ment. Then press .Page9
During a firing,
press repeatedly until
appears. Press .Use
the arrow keys to change the alarm
temperature. Press .Tosi
-
lence the alarm, press any key.
Page 9
At the display, press
. will appear. Use ar
-
row keys to adjust the controller to
fire hotter or cooler. Press
to return to .Page12
Down Arrow Key
From press
.Thepro
-
gram you have selected
will appear one step at a
time. When ap
-
pears, press .
Page 4
From
press .
Enter delay time. Press
twice. Page 4
During firing, press
. The program you
entered will appear one
step at a time. Page 4
Light is
on during pro
-
gramming.
Light is
on during pro
-
gram review.
Light
blinks during firing.
Temperature Display
Temperature
display is in °F.
Tem
-
perature display is in °C.
Seepage13forinstructionson
selecting °F or °C.
Time Display
:Sepa-
rates hours from minutes. Ex-
ample: Display shown above
is 1 hour and 30 minutes.
°F
°C
°C Display Dot
Sentry Xpress
Digital Temperature Controller
Single-Speed / Ramp-Hold Version
IM-221/2-06
Indicator
Lights
*These features are new with the Sentry Xpress 4.0. If your controller does
not have these features, it is an earlier controller.
Vista de página 0
1 2 3 4 5 6 ... 15 16

Resumo do Conteúdo

Página 1 - Sentry Xpress

The Sentry Xpress 4.0 micro processor is manufactured by theOrton Ceramic Foundation and displays the CE mark.Hr./Min.When LitHIGHER°C°FWhen OffWhen L

Página 2 - Introduction

10 Single-Speed/Ramp-HoldDisplayMessages(Page 9) Ready for you to enter an alarmtemperature. When the kiln reaches that tempera-ture, the alarm will s

Página 3 - Guidelines

11(pages 7, 8) Theseare Ramp-Hold programs stored in memory.etc. (Rate) (page 8) This appears inRamp-Hold programming for each segment. 1, 2,etc. are

Página 4 - 4 Single-Speed/Ramp-Hold

12 Single-Speed/Ramp-HoldFE Error MessagesFE 1 Memory Read/Write FailureFE 2 RAM FailureFE 3 OEM Factory Data CorruptionFE 4 Thermocouple “Noise”FE 5

Página 5 - Operation

13Trouble ShooterProblem: Controller display isblank. No heat in kiln.IIs the kiln connected to the power?IHas the circuit breaker tripped or fuse blo

Página 6 - Instructions

14 Single-Speed/Ramp-HoldProblem: Controller displayturns on. No heat in kiln.IIs the relay making its normal clicking sound?Test the elements with an

Página 7 - Ramp-Hold

15IndexAdd Hold Time. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 8 - Features

16 Single-Speed/Ramp-HoldShorthand InstructionsThese instructions may be confusing until you have read more detailed instructions on Single-Speed, pag

Página 9 - Lost Wax

2 Single-Speed/Ramp-Hold©2004, by Paragon Industries, L.P. IM-221/2-06ContentsGeneral Guidelines . . . . . . . . . . . . . . . . . 3Time and Temperat

Página 10 - Messages

3GeneralGuidelinesTime and TemperatureDisplayCenter Dot: TimeA center dot appears dur-ing time display. It separateshours from minutes. (Exam-ple: 1 h

Página 11 - Error Messages

4 Single-Speed/Ramp-HoldNote: Press during delay to end the delay andbegin the firing. The maximum delay is 99 hours and59 minutes.Power FailuresAfter

Página 12 - Thermocouple

5RateEach segment must include a rate, which is degrees oftemperature change per hour.The kiln will fire at full power when the rate is1799°F/999°C. F

Página 13 - °C Display

6 Single-Speed/Ramp-HoldRamp-Hold programs in memory. Programs are numberedPro1 - Pro4.Type of Firing Suggested Firing ModeEnameling Single-SpeedSilve

Página 14 - Problem: Controller display

7Rate Temp.Segment °F/°C °F/°C Hold1 500/277 1450/788 00.002 100/55 700/371 00.00The first segment is the heating segment. The secondone is the coolin

Página 15 - Problem: Kiln switch box ½

8 Single-Speed/Ramp-HoldAdvancedFeaturesSkip Segment works only in Ramp-Hold programs. AddHold Time, Temperature Edit, and Alarm work in bothSingle-Sp

Página 16 - Shorthand Instructions